Skip to content
DSRI — Design · Test · Measure
Equipment & capabilities

What the machines can do

Published equipment capability envelopes. Every requisition is checked against the actual machine ratings — force, displacement, payload, working space, thermal envelope — before we quote, so the profile you need is the profile you get.

These are machine ratings, not accredited ranges. Which methods (and ranges) carry NABL accreditation is defined by the scope of accreditation; anything beyond it is reported as non-accredited.

Manufacturer and product names on this page are trademarks of their respective owners, used only to identify the equipment we operate; no endorsement or affiliation is implied.

Dynamic

Vibration

Electrodynamic shakers

up to 16,000 kgf sine force — the largest in the Indian private sector · 4,000 kgf and LDS systems for smaller units · vertical head expanders and horizontal slip tables · sine, random, sine-on-random, resonance search & dwell.

MIL-STD-810 514JSS 55555 T28IEC 60068-2-6/-64MIL-STD-167-1A
Shock & bump

Shock and bump machines

Classical shock up to 30,000 g; half-sine bump 3 g – 60 g, thousands of bumps per axis; saw-tooth and trapezoidal pulses by programme.

MIL-STD-810 516JSS 55555 T24 / T5IEC 60068-2-27IS 10236-10
Acceleration & motion

Centrifuge & ship-motion simulator

The only ship-motion simulator in the Indian private sector. Steady-state acceleration 1 g – 100 g; tilt / inclination 0° – 45°; multi-axis ship-motion (roll, pitch, yaw, heave) for naval equipment.

MIL-STD-810 513JSS 55555 T1JSG 0102

Climatic

Temperature & humidity

Walk-in and bench chambers

−70 °C to +180 °C · humidity to 98 % RH · thermal cycling 15 °C/min · 2 m and 5 m walk-in rooms for racks, cabinets and vehicles-scale assemblies · CATH chamber for combined altitude / temperature / humidity.

IEC 60068-2-1/-2/-14/-30/-38IS 9000MIL-STD-810 500–507
Ingress

Dust, sand and water

Dust IP 5X / IP 6X · water IP X1 – X8 (drip, spray, jet, immersion) · driving rain and drip-proof rigs for naval specifications.

IEC/IS 60529JSS 55555 T11/T12/T14IS 9000-16
Corrosion & biological

Salt spray and mould growth

Dedicated salt-corrosion chamber and mould-growth (fungus) chamber; tropical-exposure and contamination-by-fluids programmes.

ASTM B117JSS 55555 T9/T21MIL-STD-810 508/509

Fluid flow

Pressure

Hydraulic & pneumatic rigs

Proof, leak and burst testing of valves, fittings and hoses on water, oil, air and nitrogen, up to 400 NB, at test pressures set to your specification; seat and shell tests to BS EN 12266.

NES 375BS 4368ASME F1387
Flow

Flow-coefficient loop

Cv / Kv determination and characteristic curves for control and isolation valves.

ANSI/ISA-75.01/.02
Endurance

Life-cycle & fire-type

Actuated life-cycle stands, dismantling & reassembly, pipe wracking, and fire-type testing for valve fire-safe ratings.

ANSI/AWWA C504DME SPEC 463ISO 10497

Mechanical & materials

Static & dynamic

Universal testing machines

2,500 kN and 250 kN biaxial, dynamic / fatigue-rated — a private-sector first in India — plus 2,000 kN and 75 kN machines · tensile, compression, bend, proof-load and fatigue on metals, fasteners, rebar couplers and structural samples.

ASTM E8 / A370ISO 6892IS 1608 / 16172
Fatigue

High- and low-cycle fatigue

HCF/LCF and cyclic tensile programmes for couplers and fasteners.

ASTM E466ISO 3800 / 7961ISO 15835-2
Elastomers

Rubber & conductive gaskets

Shore-A hardness, tear, compression set, low-temperature flex; MIL-DTL-83528C electrical properties.

ASTM D2240 / D624 / D395MIL-DTL-83528C

EMI / EMC and noise & vibration

Chamber

Semi-anechoic chamber

Shield-to-shield 8.0 × 6.0 × 4.5 m, semi-anechoic at a 1 m test distance, shielding validated 9 kHz – 40 GHz to IEEE-299 · 3.0 × 3.0 m pneumatic RF door onto a 4-tonne floor, so a full cabinet or skid goes straight in · 150 mm reflective ground plane, 2.5 × 1.2 × 0.9 m military test table · ambient held 6 dB below the MIL limit.

IEEE-299EN 50147MIL-STD-461 validated
Emissions

RE102 radiated emissions

10 kHz – 18 GHz at 1 m · Keysight 26.5 GHz EMI receiver with pre-amplifiers · active monopole, biconical and horn antennas across the band · single- and three-phase LISNs for the conducted suite · NEXIO BAT automation.

RE102CE101 / CE102RE101
Susceptibility

RS103 radiated susceptibility

2 MHz – 18 GHz at 1 m, guaranteed 50 V/m · 1,300 W / 250 W / 100 W / 50 W amplifier chain · R&S SMB100B source, log-periodic and horn antennas, PMM EPP603 field probe with two-channel power metering.

RS103CS114 / CS115 / CS116RS101

Accredited to MIL-STD-461 revisions E, F and G: CE101, CE102, CS101, CS109, CS114, CS115, CS116, RE101 and RS101; plus CS118 personnel-borne ESD to revision G. Electric-field radiated testing (RE102, RS103) runs in this chamber and is reported as non-accredited pending extension of the scope.

NVH

Noise & vibration measurement

Multi-channel acquisition, airborne and structure-borne noise, ISO 3744 sound power, octave-band and dB(A) reporting against MIL-STD-740 / NES 1004 limits, FRF and modal surveys, and an in-house DSP toolkit for data reduction.

Measurement

Multi-channel data acquisition

up to 80 synchronised channels · sampling up to 1 MS/s per channel · Dewesoft and HBK LAN-XI modules · every channel on one time base with the test machine's load, stroke, drive and cycle signals · for instrumented fatigue, vibration, shock and noise tests in any lab.

Analog
voltage, current, resistance, strain (bridge), IEPE accelerometers and microphones, charge, thermocouple, RTD, LVDT
Digital
digital I/O, counters, encoders, tacho
Vehicle bus
CAN, CAN-FD
Video & position
high-speed and thermal video synchronised with the data; GNSS
DewesoftHBK LAN-XI

Calibration

Accredited separately from the testing scope, under NABL certificate CC-4454. In-house calibration keeps every measurement in DSRI's own test chain traceable to national standards — and the same service is open to customers who need audit-ready calibration without sending instruments away.

DisciplineEquipment calibratedRange
ThermalClimatic chambers and ovens−70 °C to +250 °C
VibrationAccelerometers — amplitude response5 – 5,000 Hz, 0.1 g – 1 g
PressureHydraulic pressure sensors0 – 700 bar
Electro-technicalMultimeters, DAQ systems, oscilloscopes, vibration controllers—
Fixtures, custody, traceability

What surrounds the machines

  • Fixture design — in-house design and fabrication of vibration and shock fixtures; FRF surveys on request.
  • Calibrated instruments — every accelerometer, sensor and chamber on a calibration schedule tracked in our equipment register; certificates available with the report.
  • Sample custody — each unit carries a QR custody label from receipt to dispatch; condition and photographs are logged at every hand-over.
  • Capability check before quotation — profiles are verified against machine ratings (force, stroke, payload, working space, thermal envelope) automatically, then by an engineer.
At a glance
Vibration
≤ 16,000 kgf
Shock
≤ 30,000 g
Bump
3 – 60 g
Acceleration
1 – 100 g
Temperature
−70 … +180 °C
Humidity
≤ 98 % RH
Cycling
15 °C / min
Ingress
IP 5X/6X · IP X1–X8
Tensile / fatigue
≤ 2,500 kN · biaxial
EMC
MIL-STD-461 E/F/G

Will your unit fit?

Send dimensions, mass and the profile — we'll confirm the machine and quote.

Send an enquiry
Get a quote